Service Information Center:
Call us rst if you have any questions with this product. We can help you with questions about assembly
and Water Heater operation or if there are any damaged or missing parts when you unpack this unit from the
shipping box. Please call before returning to the store.
1-866-946-1096
8am-4pm CST, Monday through Friday
157140081P Date 2014/02/13
Installation Operation Manual
Natural Gas (NG) - Factory Default
Liquid Propane Gas (LPG) - Optional Ori ce
Model GU145 (S) / 508(11,12,21,22)1145 (S)
Model GU195 (S) / 508(11,12,21,22)1195 (S)
Model GU195 (M) /
508(11,12,21,22)1195 (M)
IMPORTANT:
Only specially trained and authorized personnel are permitted to service this water heater.
NOTE TO ASSEMBLER / INSTALLER:
Leave this manual with the consumer.
NOTE TO CONSUMER:
Keep this manual for future reference.
RECORD YOUR SERIAL #
________________
(see silver CSA label on Gas Water Heater)
1
Read this Operator's Manual carefully and be sure your Water Heater is properly assembled, installed and maintained.
Failure to follow these instructions exactly could result in re, explosion, serious bodily injury and/or property damage.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
WARNING
!
!
California Proposition 65 lists chemical substances known to the state to cause cancer, birth defects, death, serious
illness or other reproductive harm. This product may contain such substances, be their origin from fuel combustion (gas,
oil) or components of the product itself.
WARNING
!
!
Only a licensed professional can install Eternal units for safety and code compliance. Venting and plumbing codes can
vary by location. Installation instructions and all applicable codes must be followed or property damage, severe injury,
or death may result. Failure to use a licensed plumber or contractor, follow venting, plumbing, and building codes; or
follow installation instructions may be unlawful and will void the product warranty. Grand Hall is not responsible for any
costs incurred for repairing any problems resulting from failure to follow installation instructions or applicable codes.
WARNING
!
!
C
Vista de página 0
1 2 3 4 5 6 ... 58 59

Resumo do Conteúdo

Página 1 - IMPORTANT:

Service Information Center:Call us fi rst if you have any questions with this product. We can help you with questions about assembly and Water Heater o

Página 2 - Table of Contents

10Parts List for Model GU195(S,M) / 508(11,12,21,22)1195(S,M)KEY DESCRIPTION1 Panel, Front Assembly2 Panel, Top / Rear Assembly3 Panel, Rear4 Panel, L

Página 3 - Optional Accessories

11Pre-Installation Instructions for Your SafetyWARNINGIf you do not follow these instructions exactly, a  re or explosion could result causing proper

Página 4

12Installation PreparationUnpack the unit carefully and make sure that all accessories are put aside so they will not be lost.● Operator's manual

Página 5 -

13Condensate DisposalThe condensate drain must be  lled and unobstructed to allow  ow of condensate. The condensate should not be subjected to condi

Página 6

14Indoor InstallationClearancesFrom top of water heater 12 inches From back of unit 0.6 inchFrom front of unit 6 inches (*)From left side of unit (gas

Página 7

15Outdoor InstallationClearancesFrom top of water heater 24 inches From back of unit 0.6 inchFrom front of unit 24 inches From left side of unit (gas

Página 8

16Mobile Home InstallationRead and Review this entire Manual with special emphasis on combustion and ventilation for your safety.If you do not follow

Página 9

17Mobile Home InstallationAll primers, cleaners and cements must meet all local codes and applicable standards of the American Society for Testing Mat

Página 10

Mobile Home InstallationHow to convert to LP1. Remove front panel by loosening 5 screws.2. Locate the gas valve towards lower left of the unit.3. Loos

Página 11

19Wall MountingMounting Steps1. Install mounting brackets with 6 screws on top and bottom back of the unit.Wall Mounting For Commercial Food ServicePe

Página 12

2Table of Contents Included & Optional Accessories P3 Specifications P4 Dimensions P5 Parts & Service Parts List P6~10 Pre-Installation Instru

Página 13 - Condensate Disposal

20Floor MountingGU145(S) / GU195(S,M) can be installed standing on combustible floor surface, or on a water heater stand.Be sure to use a suitable dra

Página 14 - Indoor Installation

21Venting Intake & Exhaust MaterialAll primers, cleaners and cements must meet all local codes and applicable standards of the American Society fo

Página 15 - Outdoor Installation

22Venting Speci cationGU145(S) / GU195(S,M) is factory configured as a sealed combustion unit with dedicated intake and exhaust connections.When inst

Página 16 - Mobile Home Installation

23Vertical TerminationBelow diagrams are examples of vertical terminations.Through roof (Direct Vent) Through roof (Concentric Vent)Through roof (Powe

Página 17

24Once the vent terminal location has been determined, make a hole through the exterior wall to accommodate the vent pipe. Vent pipe must only exit ex

Página 18

25Clearance Requirements from Vent Terminations to Building OpeningsAll clearance requirements are in accordance with ANSI Z21.10.3 and the National F

Página 19 - Wall Mounting

26Multiple Units TerminationWhen two or more direct vent units are vented near each other, each unit must be individually vented, but next unit vent t

Página 20 - Floor Mounting

27Common Vent InstallationSystemsPower VentDirect Vent(Sealed Vent)POWER VENTEDDimensions Of InstallationDIRECT VENTEDNumber of installing units Comm

Página 21 - NOTICE-VENTING GUIDELINES

28Concentric Vent Kit"Y" Concentric Fitting4" DIASDR-26 Pipe2 ½" DIASDR-26 PipeRain CapExhaust Connection* Approved Grand Hall Con

Página 22

29Vent Pipe Installation & Terminator PositionDescriptionUS InstallationsCanadian Installations Other than Direct Vent Direct VentAClearance above

Página 23

3Included AccessoriesOptional AccessoriesSelf Tapping Screw 5/32" x 5/8" : 2pcsPhilips Head ScrewM8x15 : 4pcsStainless Steel Expansion Bolt

Página 24

30Gas Supply PipingWhen measuring the inlet supply pressure, the water heater and all other gas appliances sharing the gas supply line must be  ring

Página 25

31LP ConversionHow to convert to LP1. Remove front panel by loosening 5 screws.2. Locate the gas valve towards lower left of the unit.3. Loosen nut co

Página 26

32Water Supply ConnectionThe water fittings on the Eternal water heater are 3/4" NPT. If the installation site has only 1/2" plumbing throug

Página 27 - Common Vent Installation

33TYPICAL INSTALLATIONCondensate PipingThis water heater is a high ef ciency, fully condensing appliance which produces condensate during operation.

Página 28

34Temperature and Pressure Relief ValveTroubleshooting Thermal ExpansionIf a water heater is installed in a closed water supply system, such as one ha

Página 29

35Electrical ConnectionInstallation Codes:Follow the requirements of the local authority having jurisdiction. In the absence of such requirements, fol

Página 30

36Optional Remote Controller InstallationPre-Installation PreparationWiring Instructions1. Turn off the unit and unplug power cord from wall socket.2.

Página 31 - LP Conversion

37Optional Remote Controller InstallationDecide on the appropriate mounting location for the Remote Controller; consider higher positions so that the

Página 32

MCU InstallationMCU Kit ComponentsSpecifications and FeaturesApplicable Models :GU195(M) / 508(11,12,21,22)1195(M)Description:MCU kit allows multiple

Página 33

39MCU InstallationConnect Female Termination Wire(F1) to MCU Wire at the  rst unit. Do not connect F1 to the ignition termination wire.6.Plug the pow

Página 34 - From unit pump socket

4Eternal Hybrid Water Heater Technical Speci cationsModel NameGU145 / GU145(S) GU195(S) / GU195(M)Thermal Ef ciency (*) / Energy Factor98% NG / 99%

Página 35

All units networked need to be assigned a unique ID number. For example, if 3 units are used, the first unit should be assigned #1 by pushing Dipswitc

Página 36

41Recirculation System with an Eternal Water HeaterThese diagrams are for reference as basic guides. Each installation should be engineered properly a

Página 37

42Restaurant and Commercial ApplicationsSystem for rapid ON/OFF hot water usageIf the unit is not controlling the pump by the internal relay, use a Aq

Página 38

43Plumbing System for Multiple Unit ApplicationsReverse return systemIn the above drawing, there is no “path of least resistance”, water  ow will be

Página 39 - MCU Installation

44Note! EACH JOB SHOULD BE SIZED ACCORDING TO THE DESIRE OF DEMAND. Pump size for commerical application when using Eternal as heat engine to recover

Página 40

45Operating InstructionsThis water heater does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not

Página 41

46How To Use The Front Control InterfaceTo switch the water heater ON: From OFF condition Press the Power Button.When running the water by opening the

Página 42

47Ignition Cycle CounterHow To Use the Remote ControllerTo switch the water heater ON with Remote Controller, from OFF condition Press the Power Butto

Página 43

48Maintenance and ServiceTurn off the electrical power supply, the manual gas control valve, and the manual water control valve before servicing.The u

Página 44 - WARNING - Aquastat

"D" button Diagnostic Function49Applicable Model:GU145(S) / 508(11,12,21,22)1145(S)GU195(S) / 508(11,12,21,22)1195(S) GU195(M) / 508(11,12,2

Página 45

5Dimensions - GU145(S) / 508(11,12,21,22)1145(S) GU195(S,M) / 508(11,12,21,22)1195(S,M)

Página 46

50DIAGNOSTICSBefore calling for service, review the following diagnostic steps  rst for saving time and money!

Página 47 - Ignition Cycle Counter

51DIAGNOSTICSSelf MonitoringThis unit has the ability to check its own operation continuously. If an error occurs, a message will flash on the digital

Página 48

NOTE: In all cases you may be able to clear the Error Message simply by turning the hot water tap OFF, then ON again. If this does not clear the Error

Página 49

The combustion testing and adjustments must be performed by a quali ed installer, service agency or the gas supplier. All combustion analyzer must be

Página 50 - DIAGNOSTICS

54How To Check Gas CombustionProcedure for high  ringUnscrew the EC adopter cap on vent collar (see to above diagram) and connect the  ue gas analyz

Página 51

55Wiring and Connection DiagramWiring Diagram MODEL : GU145(S) / 508(11,12,21,22)1145(S) GU195(S) / 508(1

Página 52

56Wiring and Connection DiagramWiring Diagram MODEL : GU195(M) / 508(11,12,21,22)1195(M)

Página 53 - How To Check Gas Combustion

57Grand Hall Limited WarrantyGeneral Terms of Limited Warranty for ProductGrand Hall will warrant to the purchaser of this gas water heater at the ORI

Página 54

58Grand Hall Limited Warranty*See DEFINITIONS below. Limited Labor AllowanceGrand Hall will provide a pre-set labor allowance as set forth in the foll

Página 55 - Wiring and Connection Diagram

59F.A.C.T. (Factory Authorized Contractor Trained) – A licensed contractor who has been through the basic installation class held by either an Eternal

Página 56

6Parts Diagram for Model GU145(S) / 508(11,12,21,22)1145(S) GU195(S,M) / 508(11,12,21,22)

Página 57 - Grand Hall Limited Warranty

7Parts Diagram for Model GU145(S) / 508(11,12,21,22)1145(S)

Página 58

8KEY DESCRIPTION1 Panel, Front Assembly2 Panel, Top / Rear Assembly3 Panel, Rear4 Panel, Left Assembly5 Panel, Right Assembly (GU145(S))6 Panel, Botto

Página 59

9Parts Diagram for Model GU195(S) / 508(11,12,21,22)1195(S)Parts Diagram for Model GU195(M) / 508(11,12,21,22)1195(M)